Troubleshooting, repair and programming of PLCs and frequency inverters. From Siemens STEP5 through STEP7 to TIA Portal, plus Lenze drives.
Most controls considered discontinued are technically in perfect working order.
Programmable logic controllers have largely replaced contactor controls. That saves space and wiring, but moves the fault into the software. Finding it there takes experience and the right programming environment, not a successor model.
We read out the existing control, locate the fault and bring the plant back into operation. A complete replacement only comes up if it cannot be avoided technically.
That applies to the PLC repair just as much as to the drive behind it: first we find the cause, then we talk about parts.
Troubleshooting, repair and programming for Siemens SIMATIC S5 (STEP5), STEP7 and TIA Portal, including the connected pneumatic systems. For controls from other manufacturers, we check beforehand whether the right software is available to access the control.
Repair of frequency inverters of any make. Parameterisation and commissioning of Siemens and Lenze inverters, plus optimisation of speed control up to positioning tasks.
Proven machines also have to be adapted to new requirements. After an on-site visit we propose a concrete solution instead of a successor model.
We repair electronic assemblies in our own electronics workshop, so they do not need to be sent away. Faulty devices in the control cabinet, such as contactors or relays, we replace directly on site. PLC spare parts we source through long-standing supplier contacts.
An inverter rarely fails as a whole. Often it is the electrolytic capacitors, fans, power semiconductors or the control circuitry, components that can be replaced individually. A new unit is therefore not automatically the right answer.
Most inverter repair is offered as a send-in service: remove, ship, wait, reinstall. That works when it is certain that the inverter is the cause. Often, though, that is not certain at all. The fault is just as often in the parameterisation, the motor, the encoder feedback or the control by the PLC.
That is why we come to the plant first and measure there. If the electronics turn out to be faulty, they are repaired in our own workshop. If a component can no longer be obtained, we carry out an emergency repair so the line keeps running until the permanent solution is in place.
In plants that have grown over the years, the only current program version often exists only on the control itself. We back it up and archive it, together with the HMI visualisations and the frequency inverter parameters.
Yes. SIMATIC S5 controls programmed with STEP5 keep running reliably in many plants. We program, maintain and repair these systems instead of recommending a complete replacement that is not technically necessary.
In most cases, yes. Typical faults go back to electrolytic capacitors, fans, power semiconductors or the control circuitry, and these components can be replaced individually. We first check on the plant whether the inverter is the cause at all, because the fault is often in the parameterisation, the motor or the control by the PLC.
Mostly because of ambient conditions: heat in the control cabinet, dusty or blocked fans, moisture and vibration. On top of that, the electrolytic capacitors in the DC link age. Frequent mains disturbances and unfavourable load changes speed this up further.
That depends more on where it is installed than on the make. A well-ventilated inverter in a filtered control cabinet lasts much longer than the same model in a hot, dusty hall. The main wear parts are fans and electrolytic capacitors, and both can be replaced preventively before they stop the plant.
Yes. As a rule we repair electronic modules in our own electronics workshop, so they do not have to be sent away. That saves shipping and waiting for the return delivery. On site we replace faulty devices such as contactors and relays directly in the control cabinet.
That depends on the effort, and you only know that once it is clear what is causing the fault. That is why you get an honest assessment of effort, time frame and spare-parts availability before the job, so you can decide before anyone sets off. Often the phone call already clarifies what can be checked immediately and what needs to be done on site.
Yes. We create and archive the program data of controls, operator panels and frequency inverters, so a version can be restored quickly in the event of a fault. This data sits on the devices themselves, which is why a normal server backup does not capture it. What exactly is included is on the PLC data backup page.
Related services